Model ST 60 ProPlus: Infrared Thermometers measure the surface temperature on an opaque object. The units opaque sense emitted, reflected, & transmitted energy, which is collected & focused onto a detector. The unit’s electronics translate the information into a temperature reading which is displayed on the unit. The laser is used for aiming purpose only.
Temperature Range: -32 to 600 Deg C (-25 to 1100 Deg F)
Display Resolution: 0.1 Deg C (0.1 Deg F)
Accuracy: Assumes ambient operating temperature of 23 ~25 Deg C (73 ~77 Deg F) For targets above;
23 Deg C: +/- 1% of reading or 1 Deg C (+/-2 Deg F) -18 to 23 Deg C (0 to 73 Deg F) +/-2 Deg C (+/-3 Deg F) -26 to -18 Deg C (-15 to 0 Deg F) +/-2.5 Deg C (+/-4 Deg F) -32 to -26 Deg C (-25 to -15 Deg F) +/-3 Deg C (+/-5 Deg F)
Repeatability: +/- 1 Deg C (+/-2 Deg F) or +/- 0.5% of reading, whichever is greater
Response time: 500mSec
Laser max: laser turns off above 40 Deg C(104 Deg F) ambient temperature
Ambient operating range: 0 to 50 Deg C (32 to 120 Deg F)
Storage temperature: -20 to 60 Deg C (-13 to 158 Deg F) without battery
Power: 9V Alkaline or NiCd battery
Typical battery life: 20 hours with laser & backlight on 50%. 40 hours laser & backlight off
Dimensions: 8” x 6” x 2”
Approx Weight: 320g
INFRARED THERMOMETER
INFRARED THERMOMETER
Infrared Thermometer Specifications :
Specifications:
Model ST 60 ProPlus: Infrared Thermometers measure the surface temperature on an opaque object. The units opaque sense emitted, reflected, & transmitted energy, which is collected & focused onto a detector. The unit’s electronics translate the information into a temperature reading which is displayed on the unit. The laser is used for aiming purpose only.
Temperature Range: -32 to 600 Deg C (-25 to 1100 Deg F)
Display Resolution: 0.1 Deg C (0.1 Deg F)
Accuracy: Assumes ambient operating temperature of 23 ~25 Deg C (73 ~77 Deg F) For targets above;
23 Deg C: +/- 1% of reading or 1 Deg C (+/-2 Deg F) -18 to 23 Deg C (0 to 73 Deg F) +/-2 Deg C (+/-3 Deg F) -26 to -18 Deg C (-15 to 0 Deg F) +/-2.5 Deg C (+/-4 Deg F) -32 to -26 Deg C (-25 to -15 Deg F) +/-3 Deg C (+/-5 Deg F)
Repeatability: +/- 1 Deg C (+/-2 Deg F) or +/- 0.5% of reading, whichever is greater
Response time: 500mSec
Laser max: laser turns off above 40 Deg C(104 Deg F) ambient temperature
Ambient operating range: 0 to 50 Deg C (32 to 120 Deg F)
Storage temperature: -20 to 60 Deg C (-13 to 158 Deg F) without battery
Power: 9V Alkaline or NiCd battery
Typical battery life: 20 hours with laser & backlight on 50%. 40 hours laser & backlight off